TEAM ORION DIGITAL SETTING BOX VORTEX DSB ORI65020
Description
Box Program for programming the Vortex-2-Series controller. With this box, at the Vortex 2 series following parameters can be adapted and configured:
First Battery Type
Use this parameter to set the battery type used. The LVC safety shutdown system informs the user of a deep layer of the battery voltage by the
Power supply for the motor stops short. In order to prevent deep discharge of the battery, stop the ride if you notice a power loss. It is also possible to turn off the security system. The controller will function until the battery voltage is too low. Please note that some batteries can be damaged if they are deep discharged. Available settings: Auto detection LiPo, NiMH / NiCd / LiFe, No shutdown
Second Power Profile
This parameter determines the acceleration curve of the controller. Use a low value for slippery surfaces and a high value for high-traction tracks. Available settings: super fine, fine, linear, power, X-Power
Third Brake
This parameter sets the maximum braking force when it is pressed. Use a low value for slippery surfaces and a high value for high-traction tracks. Please note that high values of the charge controller more. Available settings: 0% to 80%
4th Automatic brake
This parameter determines the automatic braking power when returning the throttle lever to the neutral position. Please note that high values of the charge controller more. Available settings: 0% to 30%
5th Timing
This parameter is used to the engine characteristics
to change. A deeper timing improves efficiency and leads to a finer control behavior. A higher timing improves
performance, but at the expense of efficiency and control behavior. Some engines can be a great timing to damage the motor and / or the regulator. Please note that high values of the charge controller more. Available settings: 0% to 30%
6th Neutral behavior
This parameter determines the control response to the neutral position. A high value means that the lever must move more, until the vehicle is moving forwards or backwards or slowed down. A lower value will make the behavior around the zero point more directly. Available settings: 1 to 4
7th Operating mode
Use this parameter to specify the mode of "forward / backward" or "forward / brake" select.
Available settings: forward / backward or forward / brake
8th Defaults
Set the slider to its default settings. Available settings are: Yes or No
The parameter list is for the Vortex 2 series, and may differ from other controllers. |